Pressure logger

  • Logger and sensor height: 74 mm
  • Diameter: 22 mm
  • Measurement range: 0 – 4000 mBar
  • Accuracy: +/- 15 mBar
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 18 hrs
  • Battery duration: 440 operating hrs

Single sensor temperature logger with short sensor

  • Logger height: 58 mm
  • Sensor length: 15 mm
  • Diameter: 22 mm
  • Measurement range: 0 – 140 °C
  • Accuracy: +/- 0,1 °C
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 18 hrs
  • Battery duration: 440 operating hrs

Single sensor temperature logger with long sensor

  • Logger height: 58 mm
  • Sensor length: 200 mm
  • Diameter: 22 mm
  • Measurement range: 0 – 140 °C
  • Accuracy: +/- 0,1 °C
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 18 hrs
  • Battery duration: 440 operating hrs

Temperature logger with two long sensors

  • Logger height: 58 mm
  • Sensor length: 200 mm
  • Diameter: 22 mm
  • Measurement range: 0 – 140 °C
  • Accuracy: +/- 0,1 °C
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 18 hrs
  • Battery duration: 440 operating hrs

Combined Logger / temperature (with short sensor) and pressure

  • Logger height: 58 mm
  • Sensor length: 15 mm
  • Diameter: 22 mm
  • Measurement range temperature: 0 – 140 °C
  • Accuracy temperature: +/- 0,1 °C
  • Measurement range pressure: 0 – 4000 mBar
  • Accuracy pressure: +/- 15 mBar
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 9 hrs per sensor
  • Battery duration: 440 operating hrs

Combined Logger / temperature (with long sensor) and pressure

  • Logger height: 58 mm
  • Sensor length: 200 mm
  • Diameter: 22 mm
  • Measurement range temperature: 0 – 140 °C
  • Accuracy temperature: +/- 0,1 °C
  • Measurement range pressure: 0 – 4000 mBar
  • Accuracy pressure: +/- 15 mBar
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 9 hrs per sensor
  • Battery duration: 440 operating hrs

Combined Logger / temperature (with two long sensors) and pressure

  • Logger height: 58 mm
  • Sensor length: 200 mm
  • Diameter: 22 mm
  • Measurement range temperature: 0 – 140 °C
  • Accuracy temperature: +/- 0,1 °C
  • Measurement range pressure: 0 – 4000 mBar
  • Accuracy pressure: +/- 15 mBar
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 6 hrs per sensor
  • Battery duration: 440 operating hrs

Conductance Logger

  • Logger height: 80 mm
  • Diameter: 22 mm
  • Measurement range temperature: 0 – 100 °C
  • Accuracy temperature: +/- 0,1 °C
  • Measurement range conductivity (at 25 °C): 5 – 3000 µS/cm
  • Accuracy conductivity: +/-1,0 µS/cm (<=100 µS/cm), +/- 2,5% (>100 µS/cm)
  • Number of data points: 64.512
  • Measurement duration with 1-second-measurements: 9 hrs
  • Battery duration: 300 operating hrs
We configure your system according to your individual requirements with the sensors you need.

Reading interface with two plug positions

  • Simultaneous read out of two sensors
  • Designed for routine checks necessary in quality assurance processes for hospitals and medical practices
  • Designed for routine checks upon service and maintenance
Valilog-Software
  • Allows for an intuitive and straight forward data analysis of temperature and pressure
  • Enables easy preparation of validation reports in pdf format
  • Simple and quick setting up of the sensors “plug and play”)
  • Offers date and report templates for sterilization and thermo-disinfection processes

Reading interface with four plug positions

  • Simultaneous read out of four sensors
  • Designed for validation of sterilization, DAC and thermo-disinfection processes
  • Designed for routine checks upon service and maintenance
Valilog-Software
  • Allows for an intuitive and straight forward data analysis of temperature and pressure
  • Enables easy preparation of validation reports in pdf format
  • Simple and quick setting up of the sensors “plug and play”)
  • Offers date and report templates for sterilization and thermo-disinfection processes